1547689918157324.png



      Features

                 ------------------------------------------------------------

            ● Accurate measurements under

               both Contact and Immersion modes

            ● Extreme ease of use

               with touch screen

            ● Automatic / manual modes

            ● Auto gain control

            ● Built-in thermal printer

            ● Portable & ergonomic design




 












Precise & Accurate

A-Scan precision and accuracy, under both cataract and immersion mode, are ensured by MEDA's mature technology and professional expertise in ophthalmic field.

Comprehensive

Automatic measurements for 4 different eye types:

Normal, Cataract, Aphakic and Special.

Manual measurement also available.

Reliable

Up to 8 groups of readings automatically measured per each scan, with averaging and standard deviation for a higher level of reliability.

Convenient

Touch screen and footswitch equipped

to enable smooth operations.

Accurate Results

Automatic reading at single or multiple points

for corneal thickness;

Multiple measurements at single point for higher reliability;

Higher accuracy enabled by averaging readings.

IOP Adjustment

Intraocular pressure adjustment provides reference

for tonometer measurement;

Parameter adjustability based on user's experience.

IOL Formulae

6 popular formulae for IOL calculation;

5 major formulae for post-refractive IOL calculation.

Simple Operations

Higher accessibility of database;

Single-click for instant print-out.

Intuitive Interface

Instant switch among different formulae;

Dual-formula display for direct result comparison.

Tight Integration

Easy access between A-scan and IOL;

Axial length automatically

imported from A-scan measurement.

Patient Management

Built-in data archiving capability for

storage of up to 180 patient records.

Instant Printout

Single click print-out enabled by in-built thermal printer;

User-defined print-out options.

PC Connectivity

Uploading application software developed to

allow for communications with PC

and unlimited storage capability.

User-defined Preference

Users are free to define acoustic velocities,

IOP parameters and printing options.

1000p.png

A-Scan

Probe: 10MHz with Fixation Red Light

Total Gain: 100dB with an adjustable range of 0-50dB

Biometry Accuracy: ±0.05mm

Resolution: 0.01mm

Measuring Range: 15-40mm

Measuring Mode: Contact or Immersion

Measuring Parameters:  Anterior Chamber Depth, Lens Thickness, Vitreous Length and Axial Length

Measuring Modes:  Automatic (Normal, Cataract, Aphakic and Special, and Manual

8 Groups of Readings with Averaging & Standard Deviation




IOL Calculation

General:  SRK-II, SRK-T, BINK-II, HOLLADAY, HOFFER-Q and HAIGIS

Post-Refractive: History-derived, Refraction-derived, Double K/SRK-T, ROSA and SHAMMAS




Pachymeter

Probe Frequency: 15-20MHz

Display Resolution:  1μm

Biometry Accuracy:  ±5μm

Measuring Scope:  230-1200μm

Multiple Corneal Maps with Graphical Display




Standard Configuration

10MHz A probe (MD-1000A & MD-1000AP)

20MHz P Probe (MD-1000P & MD-1000AP)

Footswitch

Test Object

AC Adapter

Tel: 0086-22-83713828

Fax: 0086-22-83713880